Brocade Network Advisor SMI Agent Developers Guide v12.3.0 Manual de usuario Pagina 123

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 178
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 122
Brocade Network Advisor SMI Agent Developer’s Guide 107
53-1003159-01
Alert indications
4
FC2
Configuration was enabled, and now this
configuration is the active configuration.
Query: SELECT * FROM
CIM_AlertIndication WHERE
OwningEntity=SNIA and MessageID=FC2
How to trigger: Enable the zoning
configuration. You can also do this
through the CLIs zonadd, cfgsave, and
cfgenable.
AlertingManagedElement COP of Brocade_Fabric
AlertingElementFormat COP
AlertType Device Alert
OtherAlertType N/A
AlertSubType Config Enabled
PerceivedSeverity 5 (Major)
ProbableCause 123
SystemCreationClassName Brocade_Fabric
SystemName Fabric WWN
ProviderName Brocade_AlertIndication
Provider
OwningEntity SNIA
Message ZoneSet <ZoneSet
Name> was activated for
fabric <WWN>
MessageArguments ZoneSet name Fabric
WWN
FC5 Change in operational status for switch.
Query: SELECT * FROM
CIM_AlertIndication WHERE
OwningEntity=SNIA and MessageID=FC5
AlertingManagedElement COP of Brocade_Switch
AlertingElementFormat COP
AlertType Device Alert
OtherAlertType N/A
AlertSubType Switch modified
PerceivedSeverity 5 (Major)
ProbableCause 123
SystemCreationClassName Brocade_Switch
SystemName Switch WWN
ProviderName Brocade_AlertIndication
Provider
OwningEntity SNIA
Message Switch <Switch Unique
Identifier> in Fabric
<Fabric Name> status
changed to <Switch
OperationalStatus>
MessageArguments Switch WWN, fabric
WWN, switch operational
status
TABLE 14 Supported alert indications (Continued)
Message ID Trigger Property Value
Vista de pagina 122
1 2 ... 118 119 120 121 122 123 124 125 126 127 128 ... 177 178

Comentarios a estos manuales

Sin comentarios