126 Brocade Network Advisor SMI Agent Developer’s Guide
53-1003159-01
Alert indications
4
BRCD44 Multiple devices (typically within a loop)
went offline.
Query: SELECT * FROM
CIM_AlertIndication WHERE
OwningEntity=BROCADE and
MessageID=BRCD44
How to trigger: Telnet to the switch and
run the CLI portdisable portnumber
where the port is an L_Port.
AlertingManagedElement COP of Brocade_Node
AlertingElementFormat COP
AlertType Other
OtherAlertType Port Alert
AlertSubType Connected Area Offline
PerceivedSeverity 2 (Informational)
ProbableCause 123
SystemCreationClassName Brocade_Fabric
SystemName Fabric WWN
ProviderName Brocade_AlertIndication
Provider
OwningEntity BROCADE
Message One or more devices
went offline for fabric
named <WWN>
MessageArguments Fabric WWN
BRCD46 Blade faulted. This happens when a blade
is plugged in to a system running an
unsupported chassis configuration.
Query: SELECT * FROM
CIM_AlertIndication WHERE
OwningEntity=BROCADE and
MessageID=BRCD46
NOTE: BRCD46 Indication is applicable
only for FOS switches.
AlertingManagedElement COP of Brocade_Switch
AlertingElementFormat COP
AlertType Other
OtherAlertType Blade Alert
AlertSubType Blade Faulted
PerceivedSeverity 5 (Major)
ProbableCause 123
SystemCreationClassName Brocade_Switch
SystemName Switch WWN
ProviderName Brocade_AlertIndication
Provider
OwningEntity BROCADE
Message Blade faulted because
the switch <WWN> runs
under unsupported
chassis-configuration
MessageArguments Switch WWN
TABLE 14 Supported alert indications (Continued)
Message ID Trigger Property Value