Multi-Service IronWare Multicast Configuration Guide 11
53-1003032-02
Support for Multicast Multi-VRF
1
Support for Multicast Multi-VRF
Multicast Multi-VRF support for the Brocade device includes the following:
Static Mroute – As described in “Configuring a static multicast route within a VRF” you can
configure static multicast route from within a specified VRF.
PIM (PIM-SM and PIM-DM) – The procedure for configuring PIM within a VRF instance is
described in “Enabling PIM for a specified VRF” and “Enabling PIM Sparse for a specified VRF”.
DVMRP – The procedure for configuring DVMRP within a VRF instance is described in
“Enabling DVMRP for a specified VRF”.
System max parameter changes
Several changes to the system max commands have been made in support of Multicast Multi-VRF.
That includes retiring the following system max commands:
system-max multicast-route
system-max dvmrp-mcache
system-max dvmrp-route
system-max pim-mcache
system-max igmp-max-group-address
These commands which require a system reload to take effect have been replaced by the following
runtime commands:
ip max-mroute – This command replaces the system-max multicast-route command.
max-mcache – This command described in “Defining the maximum number of DVMRP cache
entries” replaces the system-max dvmrp-mcache command.
max-mroute – This command described in “Defining the maximum number of DVMRP routes”
replaces the system-max dvmrp-route command.
max-mcache – This command described in “Defining the maximum number of PIM cache
entries” replaces the system-max pim-mcache command.
ip igmp max-group-address – This command described in “Defining the maximum number of
IGMP group addresses” replaces the system-max igmp-max-group-address command.
NOTE
If the deprecated system-max commands are used, the new runtime commands will be substituted
in the running config.
Additionally, you can set a maximum value for multicast VRF CAM entries as described in “Defining
the maximum number of multicast VRF CAM entries”.
Show and clear command support
The following show and clear commands have been introduced or enhanced to support Multicast
Multi-VRF:
“clear ip dvmrp [vrf vrf-name] cache”