In this example, ICX 6450 peripheral devices are removed from a mixed stack.
The mixed stack contains two ICX 6610 devices in the backbone, and there are
two substacks containing three ICX 6450 devices each.
The following show stack output shows the configuration of the mixed stack
before the stack unconfigure mixed-stack command is executed. The show
stack command is executed on the active controller.
Brocade# show stack
alone: standalone, D: dynamic config, S: static config
ID Type Role Mac Address Pri State Comment
1 S ICX6610-24F active 748e.f891.c5b8 128 local Ready
2 S ICX6610-48P standby 748e.f834.4d14 0 remote Ready
3 S ICX6450-24 member 748e.f86d.7aa7 0 remote Ready
4 S ICX6450-24P member 748e.f8b0.7aa0 0 remote Ready
5 S ICX6450-24P member 748e.f8b0.7cc0 0 remote Ready
6 S ICX6450-48 member 748e.f8d4.02c0 0 remote Ready
7 S ICX6450-48 member 748e.f8d4.2300 0 remote Ready
8 S ICX6450-24P member 748e.f8b0.6c00 0 remote Ready
active standby
+---+ +---+
=2/6| 1 |2/1==2/6| 2 |2/1=
| +---+ +---+ |
| |
|------------------------|
active standby
--- +---+ +---+ +---+ ---
( 1 )3/7--2/1| 6 |2/3==2/1| 7 |2/3==2/1| 8 |2/3==3/7( 2 )
--- +---+ +---+ +---+ ---
standby active
--- +---+ +---+ +---+ ---
( 2 )3/1==2/1| 5 |2/3==2/1| 4 |2/3==2/1| 3 |2/3--3/1( 1 )
--- +---+ +---+ +---+ ---
Will assign standby in 23 sec due to all ready
Standby u2 - No hitless failover. Reason: hitless-failover not configured
Current stack management MAC is 748e.f891.c5b8
Note: no "stack mac" config. My MAC will change after failover.
The following show running-config output shows the configuration of each
mixed stack member. The show running-config command is executed on the
active controller.
Brocade# show run
Current configuration:
!
ver 08.0.00B3T7f3
!
stack unit 1
module 1 icx6610-24f-sf-port-management-module
module 2 icx6610-qsfp-10-port-160g-module
module 3 icx6610-8-port-10g-dual-mode-module
priority 128
stack-trunk 1/2/1 to 1/2/2
stack-trunk 1/2/6 to 1/2/7
stack-port 1/2/1 1/2/6
peri-port 1/3/1
peri-port 1/3/7
stack unit 2
module 1 icx6610-48p-poe-port-management-module
module 2 icx6610-qsfp-10-port-160g-module
module 3 icx6610-8-port-10g-dual-mode-module
stack-trunk 2/2/1 to 2/2/2
stack-trunk 2/2/6 to 2/2/7
stack-port 2/2/1 2/2/6
peri-trunk 2/3/1 to 2/3/2
peri-trunk 2/3/7 to 2/3/8
stack unit 3
module 1 icx6450-24-port-management-module
module 2 icx6450-sfp-plus-4port-40g-module
stack-trunk 3/2/1 to 3/2/2
stack-port 3/2/1 3/2/3
connect 1/3/1
Mixed Stacking
FastIron Ethernet Switch Stacking Configuration Guide 141
53-1003090-02
Vista de pagina 142