Brocade Multi-Service IronWare Switching Configuration Gui Manual de usuario Pagina 328

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 984
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 327
298 Multi-Service IronWare Switching Configuration Guide
53-1003036-02
802.1ag over PBB OAM
11
Show service-type-table output changes
The output of show service-type-table command displays the Forced VLAN Action field programmed
in the service type table entry.
Brocade#show service-type-table port 1/1
ST Service Service VLAN RX QOS TCI TC VLAN IPv4 IPv6 Mcast Forced
entry type ID valid ID valid Index ID Rtg Rtg bidir VL ACT
0x00000 0 (LEGACY) 000000 1 00000 0 - 0000 N N N N
0x00032 1 (VPLS ) 000005 1 04095 0 - 0050 Y Y N N
0x000c8 1 (VPLS ) 000003 1 04095 0 - 0200 Y Y N Y
Syntax: show service-type-table slot/port
802.1ag over PBB OAM
Connectivity Fault Management (802.1ag) is for end-to-end connectivity monitoring. The following
functionality has been added.
CFM monitoring for C-SVLAN/S-VLAN
CFM monitoring for ISID and B-VLAN
CFM monitoring for Link MA
Port status TLV
Remote Defect Indication
NOTE
PBB-OAM is not supported in the 24x10G card. Only Plain VLAN CFM is supported in the 24x10G
card.
Vista de pagina 327