530 Multi-Service IronWare Switching Configuration Guide
53-1003036-02
Configuring ERP with IEEE 802.1ag
15
Device 1 RPL owner
NOTE
Optionally, you can configure the non-revertive mode feature. This setting can only be set on the RPL
owner.
(config)# erp 1
(config-erp-1)#right-interface vlan 2 e 1/2
(config-erp-1)#left-interface vlan 2 e 1/1
(config-erp-1)#rpl vlan 2 e1/2
(config-erp-1)#rpl-owner
(config-erp-1)#enable
Device 2 RPL node
(config)# erp 1
(config-erp-1)#right-interface vlan 2 e 1/2
(config-erp-1)#left-interface vlan 2 e 1/1
(config-erp-1)#rpl vlan 2 e 1/1
(config-erp-1)#enable
Device 3 Non-RPL node
(config)# erp 1
(config-erp-1)#right-interface vlan 2 e 1/2
(config-erp-1)#left-interface vlan 2 e 1/1
(config-erp-1)#enable
Device 4 Non-RPL node
(config)# erp 1
(config-erp-1)#right-interface vlan 2 e 1/2
(config-erp-1)#left-interface vlan 2 e 1/1
(config-erp-1)#enable
Configuring ERP with IEEE 802.1ag
To configure and initialize ERP using APS and IEEE 802.1ag you must set up one RPL owner and
one or more Non-RPL nodes. Other nonparticipating switches can exist in the ring.
You must perform the following minimum configuration tasks for the RPL owner:
Configure an ERP instance
Set the left and right interfaces
Set the role as owner
Set the RPL
Vista de pagina 559