Multi-Service IronWare Switching Configuration Guide 519
53-1003036-02
Initializing a new ERN
15
Figure 133 shows the next sequence of events. The actions of each ERN are:
After the WTB timer expires, ERN 2 (RPL owner in the Pending state) transmits R-APS (NR, RB),
and then ERN 2 enters the Idle state.
ERN 1, still in the Pending state, forwards R-APS (NR, RB) and enters the Idle state.
ERN 3 takes no action.
ERN 4 from the Pending state and stops transmitting R-APS (NR).
FIGURE 133 Initializing an ERP topology - VI