Brocade Multi-Service IronWare Switching Configuration Gui Manual de usuario Pagina 961

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 984
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 960
Multi-Service IronWare Switching Configuration Guide 931
53-1003036-02
Configuring BFD for the specified protocol
25
TABLE 129 Display of BFD neighbor detail information
This field... Displays...
Total number of Neighbor entries Total number of BFD sessions.
NeighborAddress IPv4 or IPv6 address of the remote peer.
State The current state of the BFD session:
Up
Down
A.DOWN – The administrative down state.
INIT – The Init state.
UNKNOWN – The current state is unknown.
Interface The logical port on which the peer is known.
Holddown The interval in microseconds after which the session will transition to
the down state if no message is received.
Interval The interval in microseconds at which the local device sends BFD
messages to the remote peer.
R/H Heard from remote, values: Y or N where Y stand for Yes and N stand for
No; H- Single hop/Multihop Values are S and M where S stand for Single
Hop and M stand for MultiHop.
Registered Protocols Specifies which protocols are registered to use BFD on this port.
Local:
Disc Value of the local discriminator field in the BFD Control Message as
used by the local device in the last message sent.
Diag Value of the diagnostic field in the BFD Control Message as used by the
local device in the last message sent.
Demand Value of the demand bit in the BFD Control Message as used by the local
device in the last message sent.
Poll Value of the poll bit in the BFD Control Message as used by the local
device in the last message sent.
MinTxInterval The interval in microseconds during which the device will send a BFD
message from this local neighbor port to the peer.
MinRxInterval The interval in microseconds that the neighbor device waits to receive a
BFD message from the peer on this local port.
Multiplier The number of times the neighbor device will wait for the MinRxInterval
time on this port before it determines the peer device is non-operational.
Remote:
Disc Value of the local discriminator field in the BFD Control Message as
received in the last message sent by the remote peer.
Diag Value of the diagnostic field in the BFD Control Message as received in
the last message sent by the remote peer.
Demand Value of the demand bit in the BFD Control Message as received in the
last message sent by the remote peer.
Poll Value of the poll bit in the BFD Control Message as received in the last
message sent by the remote peer.
MinTxInterval The interval in milliseconds during which the device will send a BFD
message from the remote neighbor port to the peer.
Vista de pagina 960
1 2 ... 956 957 958 959 960 961 962 963 964 965 966 ... 983 984

Comentarios a estos manuales

Sin comentarios