Multi-Service IronWare Switching Configuration Guide 539
53-1003036-02
ERP commands
15
You can configure the hold-off timer in 100ms increments from 0 to 10,000 ms (10 seconds); the
default value is 0 ms. The hold-off timer value cannot be stopped through the CLI.
Syntax: holdoff-time time-value>
Configuring the message interval time
The message interval time of R-APS messages continuously sent within an ERP ring can be
configured. You can configure the interval in 100ms increments from 100ms to 5000ms (5
seconds); the default value is 5000ms.
Syntax: message-interval time-value>
Setting the ITU-T G.8032 version number
You can configure the ERP configuration to use G.8032 version 1 or 2. The default value is version
2. Table 66 lists the feature and MAC ID differences between versions 1 and 2.
NOTE
The ERP version command does not have a shortened form. You must enter the complete command.
Syntax: version version_number>
You can view the version by entering the show erp command. The version appears on the top line
directly after the ERP ID.
TABLE 66 Feature differences between G.8032 version 1 and 2
Version Supported ERP features Treatment of MAC ID
1 Signal Fail
Signal Fail recovery
Always uses 01:19:A7:00:00:01 as
the ERP ID in R-APS messages
2
Signal Fail
Signal Fail recovery
Manual Switch
Forced Switch
Non-revertive
Interconnected rings
RPL configuration on non-RPL owner
Allows use of the ERP ID for the last
two bytes of the MAC ID
(01:19:A7:00:00:erp-id)