314 Multi-Service IronWare Switching Configuration Guide
53-1003036-02
802.1ag over PBB OAM
11
Deployment Scenario-5 (BVLAN MEPs on BEBs and MIP on BCBs)
BVLAN CFM configuration will be similar to regular VLAN and it will support both MEP and MIP
functionality.
Show Commands
The show cfm command provides the following output.
Brocade#show cfm
Domain: md2
Level: 6
Maintenance association: ma2
CCM interval: 10000 ms
PBB-VPLS ID: 100
Priority: 4
MEP Direction MAC PORT
==== ========= ========= ====
2 UP 000c.dbf3.fa02 ethe 1/3
The show cfm connectivity command provides the following output.
Brocade#show cfm connectivity
Domain: md2 Level: 6
Maintenance association: ma2
CCM interval: 10000 ms
PBB-VPLS ID: 100
Priority: 4
RMEP MAC VLAN/PEER AGE PORT SLOTS
==== ===== ============ ======= ======== ====
3 000c.dbf3.fb02 10.2.2.2 320 1
The show cfm connectivity domain command provides the following output.
Brocade#show cfm co domain md2 ma ma2 rmep 3
Domain: md2 Level: 6
Maintenance association: ma2 PBB-VPLS ID: 100 Priority: 4
CCM interval: 10000 ms
RMEP MAC PORT Oper Age CCM RDI Port Intf Intvl Seq
State Val Cnt Status Status Error Error
==== =============== ===== ===== ======= ========== ==== ====== ====== ===== =====
3 000c.dbf3.fb02 00c35 OK 20 39 N 0 0 N Y
The show cfm domain domain-name ma ma-name command provides the following output.
Brocade#show cfm do md2 ma ma2
Domain: md2
Level: 6
Maintenance association: ma2
CCM interval: 10000 ms
VLL ID: 100
Priority: 4
MEP Direction MAC PORT/TX PORT
==== ========= ========= ====
2 UP 000c.dbf3.fa02 ethe 1/3
REMOTE MEP id 3 MAC 000c.dbf3.fb02 OK 2
CFM port (VL100) PBB-VPLS 100