Brocade Network OS Message Reference v4.1.1 Manual de usuario Pagina 121

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 478
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 120
Network OS Message Reference 105
53-1003227-01
BL-1012
8
BL-1012
Message bport <interface module port number> port int is disabled. Status=0x<interrupt
status>; Port <port number> will be re-enabled in a minute.
Message Type LOG
Severity ERROR
Probable Cause Indicates that the port generated an excessive number of interrupts that may prove unrecoverable to the
switch operation. The port is disabled to prevent the management module from becoming too busy. The
interface module port number displayed in the message may not correspond to a user port number.
Recommended
Action
Make sure to capture the console output during this process.
Check for a faulty cable, small form-factor pluggable (SFP) transceiver, or device attached to the
specified port.
For a modular switch, execute the power-off and power-on commands to power cycle the interface
module.
For a compact switch, reload or power cycle the switch.
If the message persists, replace the interface module or the switch.
BL-1013
Message bport <interface module port number> port is faulted. Status=0x<interrupt status>;
Port <port number> will be re-enabled in a minute.
Message Type LOG
Severity ERROR
Probable Cause Indicates that the port generated an excessive number of interrupts that may prove fatal to the switch
operation. The port is disabled to prevent the management module from becoming too busy. The
interface module port number displayed in the message may not correspond to the user port number.
Recommended
Action
Make sure to capture the console output during this process.
Check for a faulty cable, small form-factor pluggable (SFP) transceiver, or device attached to the
specified port.
For a modular switch, execute the power-off and power-on commands to power cycle the interface
module.
For a compact switch, reload or power cycle the switch.
If the message persists, replace the interface module or the switch.