Network OS Message Reference 313
53-1003227-01
NSM-2010
8
NSM-2010
Message Interface <InterfaceName> could not become non-port-profile-port.
Message Type DCE
Severity ERROR
Probable Cause Indicates that the port-profile configuration mode could not be disabled on the specified interface using
the no port-profile-port command.
Recommended
Action
Check the configuration and port-profile status using the show port-profile status command. Execute
the copy support command and contact your switch service provider.
NSM-2011
Message Port-profile <ProfileName> removal failed on <InterfaceName>.
Message Type DCE
Severity ERROR
Probable Cause Indicates that the specified port-profile could not be removed.
Recommended
Action
Execute the copy support command and contact your switch service provider.
NSM-2012
Message MAC <ProfileMac> is associated to port-profile <ProfileName>.
Message Type DCE
Severity INFO
Probable Cause Indicates successful association of the Virtual Machine (VM) Media Access Control (MAC) address with
the specified port-profile.
Recommended
Action
No action is required.