Network OS Message Reference 209
53-1003227-01
FW-1010
8
FW-1010
Message <Label>, is below low boundary(High=<High value>, Low=<Low value>). Current value
is <Value> <Unit>.
Message Type LOG
Severity WARNING
Probable Cause Indicates that the power supply is faulty. The power supply is not producing enough power.
Recommended
Action
Verify that the power supply is installed correctly and that it is correctly seated in the chassis. If the
problem persists, replace the faulty power supply.
FW-1012
Message <Label>, is between high and low boundaries(High=<High value>, Low=<Low value>).
Current value is <Value> <Unit>.
Message Type LOG
Severity INFO
Probable Cause Indicates that the power supply counter changed from a value outside of the acceptable range to a value
within the acceptable range.
Recommended
Action
No action is required. Respond to this message as is appropriate to the particular policy of the end-user
installation.
FW-1034
Message <Label>, is below low boundary(High=<High value>, Low=<Low value>). Current value
is <Value> <Unit>.
Message Type LOG
Severity WARNING
Probable Cause Indicates that the temperature of the small form-factor pluggable (SFP) transceiver has fallen below the
low boundary.
Recommended
Action
No action is required. Respond to this message as is appropriate to the particular policy of the end-user
installation.
Comentarios a estos manuales