Network OS Message Reference 361
53-1003227-01
RTWR-1001
8
RTWR Messages
RTWR-1001
Message RTWR <routine: error message> 0x<detail 1>, 0x<detail 2>, 0x<detail 3>, 0x<detail
4>, 0x<detail 5>.
Message Type LOG
Severity ERROR
Probable Cause Indicates that an error occurred in Reliable Transport Write and Read (RTWR) due to one of the following
reasons:
The system ran out of memory.
The domain may be unreachable.
The frame transmission failed.
An internal error or failure occurred.
The message contains the name of the routine that has an error and other error-specific information.
Refer to values in details 1 through 5 for more information.
Recommended
Action
Execute the reload command to restart the switch.
RTWR-1002
Message RTWR <error message: Maximum retries exhausted> 0x<port>, 0x<RBridge>, 0x<retry
count>, 0x<status>, 0x<process ID>.
Message Type LOG
Severity WARNING
Probable Cause Indicates that Reliable Transport Write and Read (RTWR) has exhausted the maximum number of retries
for sending data to the specified RBridge.
Recommended
Action
Execute the show fabric all command to verify that the specified RBridge ID is online.
If the switch with the specified RBridge ID is offline, enable the switch using the chassis enable
command.
If the message persists, execute the copy support command and contact your switch service provider.