Network OS Message Reference 341
53-1003227-01
PLAT-1007
8
PLAT-1007
Message Turning off Fan <Fan Number> because of airflow direction <Global airflow
direction>.
Message Type LOG
Severity ERROR
Probable Cause Indicates that the specified fan is turned off because of an incorrect airflow direction.
Recommended
Action
Replace the fan field-replaceable units (FRUs) in such a manner that the air flows in the same direction,
that is, towards the port side or away from the port side of the system. Refer to the Hardware Reference
Manual of your switch for instructions to replace the fan FRU.
PLAT-1008
Message Unable to read EEPROM for Global airflow direction.
Message Type LOG
Severity ERROR
Probable Cause Indicates a failure to read the electrically erasable programmable read-only memory (EEPROM) and
therefore unable to determine the global airflow direction of the fans.
Recommended
Action
Execute the copy support command and contact your switch service provider.
PLAT-1009
Message Unable to read EEPROM Valid Signature for Global airflow direction.
Message Type LOG
Severity ERROR
Probable Cause Indicates that the content read from electrically erasable programmable read-only memory (EEPROM) is
invalid and therefore unable to determine the global airflow direction of the fans.
Recommended
Action
Execute the copy support command and contact your switch service provider.
Comentarios a estos manuales