Brocade Network OS Message Reference v4.1.1 Manual de usuario Pagina 131

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 478
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 130
Network OS Message Reference 115
53-1003227-01
BLL-1000
8
BLL Messages
BLL-1000
Message ASIC driver detected <slot string> port <port number> as faulty (reason: <reason
code>).
Message Type FFDC | LOG
Severity CRITICAL
Probable Cause Indicates that an interface module regulation problem was reported on the specified slot. The interface
module is faulted.
The reason codes are as follows:
1 = Available buffer overflow
2 = Backend port buffer timeout
3 = Backend port got shut down
4 = Embedded port buffer timeout
5 = Excessive busy mini buffer
6 = Excessive RCC VC on E_Port
7 = Excessive RCC VC on FL_Port
8 = Fail detection buffer tag error
9 = Fail detection TX parity error
10 = EPI CMEM interrupt error
11 = Checkpoint Middleware Interface (CMI) interrupt error
12 = Interrupt overrun
13 = FDET interrupt
14 = Interrupt suspended
15 = Filter LISTD error
16 = Unknown filter LIST error
17 = Wait for LPC open state
18 = Wait for Old port state
19 = Wait for Open init state
20 = TX parity error
21 = RAM parity error
22 = Built in Self Repair (BISR) or RAMINIT error
Recommended
Action
Make sure the interface module is seated correctly. If the interface module is seated correctly, reload or
power cycle the interface module using the power-off and power-on commands.
Execute the diag systemverification command to verify that the interface module does not have
hardware problems.
If the message persists, replace the interface module.
Vista de pagina 130
1 2 ... 126 127 128 129 130 131 132 133 134 135 136 ... 477 478

Comentarios a estos manuales

Sin comentarios