434 Network OS Message Reference
53-1003227-01
TS-1002
8
TS Messages
TS-1002
Message <Type of clock server used> Clock Server used instead of <Type of clock server
configured>: locl: 0x<Reference ID of LOCL> remote: 0x<Reference ID of external
clock server>.
Message Type LOG
Severity INFO
Probable Cause Indicates that the switch time synchronization was sourced from an alternate clock server instead of the
configured clock server. The clock server used can be one of the following type:
LOCL - Local switch clock.
External - External Network Time Protocol (NTP) server address configured.
This message may be logged during temporary operational issues such as IP network connection issues
to the external clock server. If the message does not recur, it can be ignored.
Recommended
Action
Execute the show ntp status command to verify that the switch clock server IP address is configured
correctly. Verify if this clock server is accessible to the switch and functional. If it is not accessible or
functional, configure an accessible and functional clock server or reset the clock server to local clock
server (LOCL).
TS-1008
Message <New clock server used> Clock Server used instead of <Old server configured>.
System time changed from <Old time> to <New time>.
Message Type LOG
Severity INFO
Probable Cause Indicates that the source of switch time synchronization was changed to another configured clock server
because the Network Time Protocol (NTP) query to the current active external clock server failed.
Recommended
Action
No action is required. New clock server synchronization will adjust the clock time.