Network OS Message Reference 165
53-1003227-01
EM-1080
8
EM-1080
Message <FRU Id> is being faulted (<return code>) because it was so faulted before
failover.
Message Type LOG
Severity INFO
Probable Cause Indicates that the specified interface module or fan was faulted prior to the most recent failover, and that
state and reason code are being carried forward.
Recommended
Action
Reseat the FRU.
Execute the diag systemverification command to verify that the switch does not have hardware
problems.
If the problem persists, replace the FRU.
EM-1100
Message Unit in <Slot number or Switch> with ID <FRU Id> is faulted(<Fault>). <Current
attempt number> of <Total number of attempts> total attempt(s) at auto-recovery is
being made. Delay is <Delay time in seconds> seconds.
Message Type CFFDC | LOG
Severity CRITICAL
Probable Cause Indicates that a fault that has been determined to be auto-recoverable has happened and recovery is
being attempted.
Recommended
Action
If auto-recovery does not happen gracefully in a reasonable time frame, follow the user guide to recover
the blade.
EM-1101
Message Unit in <Slot number or Switch> with ID <FRU Id> is faulted(<Fault>). <Current
attempt number> attempt(s) at auto-recovery were made without success.
Message Type LOG
Severity CRITICAL
Probable Cause Indicates that a fault that has been determined to be auto-recoverable has happened but recovery failed.
Recommended
Action
Follow the user guide to recover the blade.