Network OS Message Reference 225
53-1003227-01
FW-1500
8
FW-1500
Message Mail overflow - Alerts being discarded.
Message Type LOG
Severity WARNING
Probable Cause Indicates that a mail alert overflow condition has occurred.
Recommended
Action
Resolve or disable the mail alert using the system-monitor-mail fru command.
FW-1501
Message Mail overflow cleared - <Mails discarded> alerts discarded.
Message Type LOG
Severity INFO
Probable Cause Indicates that the mail overflow condition has cleared.
Recommended
Action
No action is required.
FW-1510
Message <Area string> threshold exceeded: Port <Port number> disabled.
Message Type LOG
Severity INFO
Probable Cause Indicates that the specified port is now disabled because the link on this port had multiple link failures
that exceed Fabric Watch (FW) threshold on the port. The link failures occurred due to one of following
reasons:
• Physical and hardware problems on the switch.
• Loss of synchronization.
• Hardware failures.
• A defective small form-factor pluggable (SFP) transceiver or faulty cable.
Protocol errors indicates cyclic redundancy check (CRC) sum disparity. Occasionally, these errors occur
due to software glitches. Persistent errors occur due to hardware problems.
Recommended
Action
Check for concurrent loss of synchronization errors. Check the SFP transceiver and the cable and
enable the port using the no shutdown command.