Network OS Message Reference 369
53-1003227-01
SEC-1193
8
SEC-1193
Message Security violation: Login failure attempt via <connection method>. IP Addr: <IP
address>.
Message Type LOG
Severity INFO
Probable Cause Indicates that a login security violation was reported. The wrong password was used while trying to log in
through the specified connection method; the log in failed. The violating IP address is displayed in the
message.
Recommended
Action
Verify that the specified IP address is being used by a valid switch administrator. Use the correct
password.
SEC-1197
Message Changed account <user name>.
Message Type LOG
Severity INFO
Probable Cause Indicates that the specified account has changed.
Recommended
Action
No action is required.
SEC-1199
Message Security violation: Unauthorized access to serial port of switch <switch
instance>.
Message Type LOG
Severity INFO
Probable Cause Indicates that a serial connection policy security violation was reported. An attempt was made to access
the serial console on the specified switch instance when it is disabled.
Recommended
Action
Check to see if an authorized access attempt was made on the console. If so, add the switch World Wide
Name (WWN) to the serial policy using the secpolicy defined-policy scc_policy member-entry
command. If the host is not allowed access to the fabric, this is a valid violation message and an
unauthorized entity is trying to access your fabric. Take appropriate action as defined by your enterprise
security policy.