Network OS Message Reference 185
53-1003227-01
FCOE-1032
8
FCOE-1032
Message The chassis is in WARM RECOVERING state.
Message Type DCE
Severity INFO
Probable Cause Indicates that the chassis is in a warm recovering state and therefore cannot perform the
protocol-specific actions for the time being.
Recommended
Action
Wait until the chassis has fully recovered before you perform any operations.
FCOE-1034
Message FIP/FCoE frame on priority <pkt_ctrlp->pri_in> for <Name of the following string>
<MAC address or WWN of the source device> on interface <Interface Name> discarded
because PFC/FCoE not enabled on this priority.
Message Type DCE
Severity WARNING
Probable Cause Indicates that the specified priority is not priority-based flow control (PFC) or Fibre Channel over Ethernet
(FCoE) enabled.
Recommended
Action
Change the CEE map assigned to the FCoE map to accommodate the PFC for the specified FCoE
priority or change the FCoE priority using the fabric-map default command under the FCoE
configuration mode.
FCOE-1035
Message Virtual FCoE port <port number> is online.
Message Type DCE
Severity INFO
Probable Cause Indicates an administrative action on the Fibre Channel over Ethernet (FCoE) port.
Recommended
Action
No action is required.