Network OS Message Reference 137
53-1003227-01
DCM-1202
8
Recommended
Action
No action is required.
DCM-1202
Message FIPS Zeroize operation: failed as VCS is enabled for this node.
Message Type LOG
Severity ERROR
Probable Cause Indicates that the Federal Information Protection Standard (FIPS) Zeroize operation has failed because
VCS is enabled on the node.
Recommended
Action
Execute the no vcs enable command to disable the VCS mode and then perform the Zeroize operation.
DCM-1203
Message FIPS Zeroize operation: confirmed that VCS is not enabled for this node.
Message Type LOG
Severity INFO
Probable Cause Indicates that VCS is not enabled on the node and therefore the Federal Information Protection Standard
(FIPS) Zeroize operation will proceed.
Recommended
Action
No action is required.
DCM-1204
Message FIPS Zeroize operation: all client sessions are notified that Zeroize in progress.
Message Type LOG
Severity INFO
Probable Cause Indicates that all client sessions are notified about the Federal Information Protection Standard (FIPS)
Zeroize operation in progress and the commands cannot be executed.
Recommended
Action
No action is required.