154 Network OS Message Reference
53-1003227-01
EM-1011
8
EM-1011
Message Received unexpected power down for <FRU Id>, but cannot determine if it has power.
Message Type FFDC | LOG
Severity CRITICAL
Probable Cause Indicates that the environmental monitor (EM) received an unexpected power-down notification from the
specified field-replaceable unit (FRU). However, after 4 seconds it could not be determined if it has
powered down or not.
Recommended
Action
Reseat the interface module. If the problem persists, replace the interface module.
EM-1012
Message <FRU Id> failed <state> state transition, unit faulted.
Message Type FFDC | LOG
Severity CRITICAL
Probable Cause Indicates that a switch interface module or compact switch failed to transition from one state to another. It
is faulted. The specific failed target state is displayed in the message. There are serious internal Network
OS configuration or hardware problems on the switch.
Recommended
Action
Reload or power cycle the switch.
Execute the diag systemverification command to verify that the switch does not have hardware
problems.
If the problem persists, replace the FRU.
EM-1013
Message Failed to update FRU information for <FRU Id>.
Message Type LOG
Severity ERROR
Probable Cause Indicates that the environmental monitor (EM) was unable to update the time alive or original equipment
manufacturer (OEM) data in the memory of an field-replaceable unit (FRU).
Recommended
Action
The update is automatically attempted again. If it continues to fail, reseat the FRU.
If the problem persists, replace the FRU.