Brocade Network OS Message Reference v4.1.1 Manual de usuario Pagina 122

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 478
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 121
106 Network OS Message Reference
53-1003227-01
BL-1014
8
BL-1014
Message bport <interface module port number> port int is disabled. Status=0x<interrupt
status>.
Message Type LOG
Severity ERROR
Probable Cause Indicates that the port generated an excessive number of interrupts that may prove fatal to the switch
operation. The port is disabled to prevent the management module from becoming too busy. The
interface module port number displayed in the message may not correspond to the user port number.
Recommended
Action
Make sure to capture the console output during this process.
For a modular switch, execute the power-off and power-on commands to power cycle the interface
module.
For a compact switch, execute the reload command to reload the switch.
Execute the diag systemverification command to determine if there is a hardware error.
Execute the diag post command to make sure that Power-On Self-Test (POST) is enabled.
If there is a hardware error, the power-off or power-on command fails on the modular switch, or the
errors are encountered again, replace the interface module or the switch.
BL-1015
Message bport <interface module port number> port is faulted. status=0x<interrupt status>.
Message Type LOG
Severity ERROR
Probable Cause Indicates that the port generated an excessive number of interrupts that may prove fatal to the switch
operation. The port is disabled to prevent the management module from becoming too busy. The
interface module port number displayed in the message may not correspond to the user port number.
Recommended
Action
Make sure to capture the console output during this process.
For a modular switch, execute the power-off and power-on commands to power cycle the interface
module.
For a compact switch, execute the reload command to reload the switch.
Execute the diag systemverification command to determine if there is a hardware error.
Execute the diag post command to ensure that Power-On Self-Test (POST) is enabled.
If there is a hardware error, the power-off or power-on command fails on the modular switch, or the
errors are encountered again, replace the interface module or the switch.
Vista de pagina 121
1 2 ... 117 118 119 120 121 122 123 124 125 126 127 ... 477 478

Comentarios a estos manuales

Sin comentarios