Network OS Message Reference 175
53-1003227-01
FABR-1056
8
FABR-1056
Message Port <port number> Disabled: Insistent RBridge ID <RBridge ID> could not be
obtained. Principal is trying to assign RBridge ID <RBridge ID>.
Message Type LOG
Severity ERROR
Probable Cause Indicates that the switch received an RBridge ID other than the one it requested. The port was disabled
because the requested insistent RBridge ID could not be obtained.
Recommended
Action
RBridge ID conflict must be reconciled with the Principal configuration. Either set the RBridge ID of the
local RBridge to match the configuration on the Principal using the vcs rbridge-id command, or remove
the conflicting RBridge from the cluster using the no vcs enable rbridge-id command. If you remove the
conflicting RBridge from the cluster, you will need to toggle the disabled port using the no fabric isl
enable and fabric isl enable commands.