Message S<slot number>,P<port number> (<interface port number>): Primitive received with
Encoding errors, do AL_RESET.
Message Type LOG
Severity WARNING
Probable Cause Indicates encoding errors on the internal links. This error can cause cyclic redundancy check (CRC)
errors or frame loss.
Recommended
Action
Whenever the error is observed persistently, power cycle the specified interface module using the
power-off and power-on commands. If the problem persists, check the backplane or replace the
interface module.
C2-1012
Message S<slot number>,P<port number> (<interface module port number>): Link Timeout on
internal port ftx=<frame transmitted> tov=<real timeout value> (><expected
timeout value>), interface module may need to be reset or replaced.
Message Type LOG
Severity WARNING
Probable Cause Indicates that above normal errors were observed in hardware that may or may not impact the data
traffic.
Recommended
Action
Whenever the error is observed persistently, power cycle the specified interface module using the
power-off and power-on commands. If the problem persists, replace the interface module.